01 Protection is part of the circuit02 Length changes cable size quickly03 The finder cites the row it usesMaximum current and extension length drive the answer. Thrust alone does not.
01
Protection is part of the circuit
A manual-reset, trip-free marine breaker or correctly rated fuse protects the ungrounded conductor. It is not an optional accessory to add after the battery and motor have been chosen.
02
Length changes cable size quickly
Manufacturer tables size extensions around maximum current and permitted voltage drop. A cable that works at five feet may be substantially undersized at twenty feet.
- Use the exact motor's published maximum current
- Measure the extension from battery to motor leads
- Use marine-grade cable with the specified temperature rating
- Do not extend a lead when the manufacturer explicitly says not to
- Use a qualified marine technician beyond published table limits
03
The finder cites the row it uses
RigCurrent only outputs a wire size when a manufacturer table covers the selected motor and length. Otherwise it tells you to keep factory leads or obtain model-specific approval.
Sources
Primary references
We link to manufacturer material so you can check the exact wording and current revision before installing or buying.
Minn Kota conductor and breaker table ↗